Cleaning the Aftercooler/
Intercooler Coils (continued)
5 Clean the assembly using a mild soap and water. Let the assembly
dry thoroughly before installation.
NOTE: In cases of heavy volatiles, steam cleaning or the use of solvents, such
as acetone, may be necessary. Be sure to test a small area with the solvent
you have selected to be sure there is no adverse reaction.
6 Inspect the condition of the gasket. If it is damaged, replace the
gasket.
7 Reassemble by repeating the steps in reverse order.
8 Connect the water supply line to the inlet. If a manual shut off
valve is used, it should be mounted on the inlet line as well.
9 Connect the outlet of the aftercooler/intercooler to the inlet of the
flow control valve using the pre-shaped copper tubing and compres-
sion fittings provided.
5-10 l Maintenance