5.2.3 EN 61000-4-4, Conducted Transients Susceptibility
The test sample was connected to the test equipment, as shown in Figure 5.2.3, and monitored for
performance. The test level was set, and the test signal was applied for the required time to one side of the line
(L). When an error occurred, the test level was reduced until the error recovered and then increased until the
threshold level was reached. This threshold and the error conditions were noted. This procedure was then
repeated while injecting into Neutral (N) ground and then to L and N together. Using a capacitive coupling
plate, as called out in EN 61000-4-4, the procedure was then repeated on signal and I/O lines whenever this
was applicable.
Figure 5.2.3 Conducted Susceptibility Test Configuration
EUT
L < 1m
A.C. mains interconnection
Protective earth according to
system installation
Table (wooden)
Protective earth
To a.c. mains supply
EFT/B - 100 test
generator with coupling/
decoupling device
Insulating support Insulating support Insulating support
L
2
<1mL
1
<1m
Capacitive coupling
clamp
EUTEUT
A.C. mains supply
A.C. mains
supply
0.1 m
To EFT/B-100 generator
0.1 m