EMC Report No: 3109178NYM-005
Page 16
5.2.6 EN 61000-4-5, Power Line Conducted Surge Susceptibility
The test sample was connected to the test equipment, as shown in Figure 5.2.6, and monitored for
performance. The test level was set and the test signal was applied between one side of the line (L1) and
ground. When an error occurs, the test level is reduced until the error recovers and then increased until the
threshold level is reached. This threshold and the error conditions were noted. If no error was detected, the
injected voltage was increased to the next test level. This procedure was then repeated while injecting into
line 2 (L2). The pulse was then applied between L1 and L2 and again in common mode from both lines-to-
ground.
Five pulses in each polarity (+), at each voltage level (0.5, 1, 2 kV) were applied in each configuration (L1-
PE, L2-PE, L1/L2-GND) and voltage level (0.5, and 1 kV were applied in L1-L2 configuration. Each pulse
was spaced approximately 30 seconds apart.
Figure 5.2.6 Power Line Conducted Surge Susceptibility
EUT
Combination Wave
Generator
C = 18uF
Decoupling Network
Earth Reference
L
N
PE
AC(DC)
Power
Supply
Network